Call 1-800-827-7502

Welcome!

Coag-Sense Professional System


  • First system with Direct Clot Detection Technology

  • Accurate results in less than one minute

  • Ability to run whole blood or plasma samples

  • Not dependent on hemoglobin and hematocrit levels

  • Superb precision (CV 2.5%) • Small sample size (10 µl minimum) for easy dosing

  • True functional controls using actual thromboplastin and plasma

  • Barcoding on each test strip - no calibration code input or chip required

SKU: CS-03P60-01R

Availability: In stock

$1,297.00
CoaguSense

Information on contract pricing

Details

Details

A Breakthrough in PT/INR Testing
  • First system with Direct Clot Detection Technology
    • Micro-mechanical process offers superb accuracy and precision
    • Not susceptible to changes in Hemoglobin & Hematocrit Levels
    • Ability to run whole blood or plasma samples
  • Barcoding on each test strip
    • Validates strip outdate – no calibration code input or chip required
  • Internal verification
    • Performs a system self-check each time a strip is inserted
  • Displays PT results in less than 1 minute
    • Calculates actual PT time without look-up table or curve-fitting algorithm
    • Allows for immediate patient consultation
Simple, accurate sample collection
  • Requires a small sample size
    • Just one drop (10 μL) of blood
  • Uses sample transfer tubes (included)
    • Allows steady transfer of sample to test strip
    • Reduces strip waste by insuring correct volume delivered
    • Supports blood borne pathogen control efforts
A more direct approach to INR testing
  • Measures actual time required for clotting
    • The only portable monitoring system that directly detects clotting endpoint – a system that emulates the WHO reference method
  • Allows greater confidence in results
    • The patented technology of direct clot detection delivers accurate and precise (CV 2.5%) results even in the high INR range (>4.0)
    • Reportable range 0.8–8.0 INR
  • True functional controls included
    • Two low and high controls using actual thromboplastin reagent and plasma of known INR included with each box of patient test strips.
Extending your control from office to home
  • Consistency of monitoring between your office and patient’s home
    • Same system provides consistent results; may help patients become more compliant under your supervision
  • Convenience of portable, stable tabletop design
    • Combined with sample transfer method, helps patients with limited motor skills steadily apply fingerstick sample
  • Independent Diagnostic Testing Facility (IDTF) supervision
    • Coordinates patient’s home testing results; reports results to you; can help improve testing adherence, insurance adjudication, and ordering supplies
    • Reduces burden on you, freeing you to manage more complex patient cases
  • Reimbursable
    • Medicare covers weekly home PT/INR monitoring for patients with mechanical heart valves, chronic atrial fibrillation, or venous thromboembolism

Additional Info

Additional Info

Quantity 1
Test Type PT/INR
CLIA Status Waived
Manufacturer CoaguSense
Platform Coag-Sense
Specifications
Cleared for home use Yes
Cleared for professional use Yes
Sample size 1 drop (10 μL) capillary blood minimum
Sampling method 21g lancet; sample transfer tube
Device specifications Portable
Size 3 in (7.6 cm) x 6.5 in (16.5 cm) x 5.75 in (14.5 cm)
Weight 1.2 lb (0.5 kg) with batteries
Test strips packaging Individually pouched in boxed quantities
Storage Non-refrigerated, up to 24-month outdate
Tracking Barcoded
Heparin sensitive Yes
Clot detection principle Direct; measures actual time required for clotting
INR range 0.8–8.0
ISI ~1.0
Prothrombin time (PT) 8–80 seconds
Analysis time <1 minute
QC External
Memory 100 tests
Barcoded test strips Yes
Power source 4 AA batteries/AC adapter (professional only)
Warranty 1 year with immediate replacement

You may also be interested in the following product(s)